The EG4 6000XP is a 48V off-grid inverter/charger that packs 6kW of 120/240V split-phase power, two 480V solar charge controllers and a 125A battery charger into one wall-mounted unit. Run a cabin, shop or full off-grid home on solar and batteries, let the grid or a generator fill in when you need it, and add units as your loads grow.
6,000W continuous at 120/240V split-phase with a 12,000W surge for about 3.5 seconds, expandable to 16 units in parallel (96kW)
Two MPPT inputs (one string each) accept up to 480Vdc and use up to 8,000W of solar, 4,000W per input, across a 120 to 385V tracking range
17A usable and 25A short-circuit current per MPPT, with arrays up to 10,000W supported for oversizing
Works with 48V lithium or lead-acid batteries, with 140A discharge and up to 125A charging (115A from grid or generator)
50A pass-through on both the grid and generator inputs, plus a two-wire generator start contact
Idle draw under 30W on solar and about 50W on battery
Listed to UL 1741 and CSA C22.2 No. 107.1, and to UL 9540 as a system with the EG4 Indoor WallMount 280Ah battery
25.5 × 18 × 5.25 in (648 × 457 × 132 mm) H×W×D, 52.9 lbs (24 kg), shipped with the Wi-Fi module, battery comm cable and parallel comm cable
Current Connected is YOUR EG4 Electronics product specialist
This product is currently unavailable. Consider one of these alternatives.

The EG4 6000XP (also referenced as SKU 1511090 by other retailers) puts a complete off-grid power center in one wall-mounted box: inverter, battery charger, two solar charge controllers and built-in disconnects. Its high-frequency, transformerless design delivers 120/240V split-phase output from a single unit, so a 240V well pump runs right alongside your 120V circuits.
Set it to run on solar and batteries first, with the grid or a generator stepping in to charge the bank and carry loads when the sun comes up short. If the grid drops, it transfers to battery in under 15 ms, so it backs up critical loads like a UPS, and its pure sine output (under 3% THD) suits sensitive electronics. Idle draw stays under 30W on solar and about 50W on battery. One customer living off grid full time in southwest New Mexico found the low idle draw holds up in real use.
Each MPPT input takes one string up to 480Vdc and tracks between 120 and 385V, so long strings of high-voltage panels run on 10 AWG wire. The inverter uses up to 4,000W per input (8,000W total), and EG4 supports arrays up to 10,000W, so you can oversize for winter sun and cloudy mornings. Keep each string under 17A operating and 25A short-circuit current, with cold-weather Voc below 480V.
PV conductors land on terminals in the wiring compartment (10 AWG recommended, up to 6 AWG, 10.6 in-lbs or 1.2 Nm), and a switch on the side isolates the solar inputs for service. EG4 calls for a separate 600V DC disconnect between the array and the inverter, four-pole when you run both strings, and a four-pole rooftop PV disconnect handles that in one NEMA 4X box. Arc-fault and ground-fault protection on the PV side are built in.
Dedicated generator terminals with a 50A pass-through let a generator charge the batteries and carry loads at the same time, no transfer switch needed. A two-wire start contact fires the generator when the battery reaches your set voltage or state of charge, then opens again once charging is done. EG4 recommends generator capacity of at least 1.5 times the inverter's output (over 10kW for one unit) with under 3% THD, and keeping combined load and charge current at or below 50A.
The same terminals accept AC coupling, so an existing grid-tied solar inverter can charge your batteries through the 6000XP (up to 50A AC) while the MPPTs add up to 8kW of DC solar. The internal neutral-ground bond is a fixed setting that stays on or off regardless of the input source, so set it to match how your generator and main panel are bonded.
Closed-loop CAN or RS485 communication lets the 6000XP read voltage, current and state of charge straight from the BMS and charge the way the battery asks. It talks to EG4 48V batteries and to other brands on EG4's compatibility list, including Pytes, and any 48V lithium or lead-acid bank can run open loop on voltage settings. EG4 recommends at least 200Ah of battery per inverter.
Pair it with the EG4 Indoor WallMount 280Ah and the combination carries a UL 9540 system listing, which helps when your AHJ (Authority Having Jurisdiction) asks for a listed energy storage system. With closed-loop EG4 batteries, the rapid shutdown switch also disconnects the battery system as NEC requires.
EG4 specifies 1 AWG battery cable torqued to 97 to 106 in-lbs (11 to 12 Nm). Our custom battery cables are crimped to order in the gauge and length your layout needs.
Each 6000XP supplies 6kW continuous, and each 120V leg carries up to 3,000W, so spread big 120V loads like a microwave and a window AC across both legs. When the house needs more, link up to 16 units for 96kW, or configure three units for 120/208V three-phase service. The included parallel cable connects the first pair, and one rapid shutdown switch on the primary inverter shuts down every unit in the system.
If you'd rather power a bigger home from a single box, the EG4 12000XP puts 12kW into one unit.
Not sure how many units your loads need? Our team is happy to help with sizing.
The 6000XP mounts upright on a solid, non-combustible wall using the included template and anchors. It's rated IP20, so give it a dry, protected spot between 32 and 113°F (0 to 45°C) and below 6,561 ft (2,000 m), with 19.7 in (500 mm) of clearance to the next unit. Grid, generator and load wiring lands on 8 AWG terminals at 18 in-lbs (2 Nm), and EG4 calls for at least a 50A loads subpanel per inverter.
The RSD (Rapid Shutdown) terminals support a system that meets 2017 and 2020 NEC 690.12, using a compatible RSD transmitter or a normally open E-stop switch (sold separately). The included Wi-Fi module connects to EG4's Monitor Center and app for live power flow, history, settings and firmware updates from anywhere, and the built-in LCD handles the same settings at the unit.
No. The PV inputs are terminals inside the wiring compartment, one string per MPPT. Your array's MC4 leads end at the DC disconnect or combiner, and standard PV wire continues from there to the inverter.
No. The 6000XP is an off-grid inverter that uses the grid for battery charging and pass-through, not export. It's listed to UL 1741 and CSA C22.2 No. 107.1 as an off-grid inverter. UL 1741 SB covers the grid-support functions utilities require from exporting inverters, so it doesn't apply here. To sell power back, look at a hybrid inverter such as the EG4 FlexBOSS18.
Yes. EG4 lists battery-free operation in off-grid mode, running loads straight from solar. Output then rises and falls with the sun, so most systems add a battery bank for steady power and surge headroom.
Two 6000XPs in parallel match the 12000XP's 12kW of output and use up to 16kW of solar across four MPPTs. You can start with one unit and add the second when your loads grow. The 12000XP fits 12kW and up to 24kW of usable solar in a single box, so it takes less wall space and wiring.
Yes. With firmware 190D0E or newer it runs 120V-only, at roughly half its rated output and charging. It also offers output settings from 200 to 240V for systems that need them.
EG4 covers the 6000XP with a 5-year standard warranty. Terms and registration are on EG4's warranty page.
Now need to upgrade and im loyal to Current Connected vs Signature Solar!
Amazing inverter, very easy to setup. I am using it as power backup solution together with EG4 48v V2 battery. Thanks to current connected for super fast shipping and good price.
I've had mine running for about a month now, using one EG4 indoor wall mount battery. While it works okay, there are several issues that have me wishing I'd gone with the 12K instead. 1. There is no load balancing on the 6000XP. In our kitchen we have several appliances (toaster oven, Induction burner, microwave, etc.) that have a high draw. Everything works fine on-grid. However we frequently experience the inverter fail due to "overload" on one leg. i.e. If we start the microwave (1875W) and an induciton burner (1800W) at the same time, the inverter will cease output. I thought, "hey that's only 3675W and this thing is supposed to support 6000W easily". Well, no, I'm told by support that it only supports 3000W per leg, no load balancing. So this kinda sucks as my whole kitchen seems to be on L1. Not an issue if on the grid, but the 6000XP can't handle all the loads. 2. Usage data is not avaialable unless the unit is connected to the internet. Since we are off-grid, and don't use wifi, this is a ridculous requirement in my view. Troubleshooting issues is very difficult without having the relevant data to review, locally. Why does EG4 insist my system has to report into their servers in order to read my local data? Not happy. I am happy with how the unit performs during the daytime in general, with our loads easily handled by direct solar. Battery charing is also very satisfactory.
I bought mine in March 2024. It was a replacement for the 6000ex which suffered an internal failure after about two years. The ease of installation far supersedes the very heavy 6000ex. The user panel where you make the connections is more roomy than the 6000ex. The built in breakers for Line in, Generator in, and Line out are a real plus. Sadly missing a pre-charge circuit, maybe in the next iteration. The remote management through the web site is light years ahead of the software for the 6000ex. It is also sad that the android app has less functionality. We have this installed in our full time off grid skoolie with 4K plus of real time solar input and an 1100AH DIY battery. It lets us live almost like we are grid tied, without the wires. This summer is being a hot one and and we are having to turn off one air conditioner to run the Microwave, because, a 1100W AC unit and a 2200W microwave push the limit of the 3000W per line output. No load balancing. But for $1399.00 that's not a surprise. We are preparing to pull the trigger on a second 6000xp to handle the extra loads of wanting to live like an eskimo in a big metal box in the Chihuahua desert of SW New Mexico One thing I forgot to mention is that the low idle current claims are verified in real world use. Which is one of the reasons we have decided on #2. We are planning to run the air conditioning circuits alone on the second inverter which will be really underutilizing the potential. In our book it should just make it last longer. We will be making the purchase of our second 6000XP from Current Connected because we had a real customer support nightmare with Signature Solar and have had a number of conversations with, Current Connected, that indicate it is far less likely to be the case here.
Amazing inverter, very easy to set up. Handles the EG4 minisplit with no issues.