Victron MultiPlus-II 48/5000 120V Inverter Charger, 48V 5kVA, 4kW Continuous, 9kW Surge, 70A Charger, Split Phase Capable, UL 1741 & UL 458


SKU: PMP482505120

$1,307.30

Log in to check member price and detailed stock information.

Need more than what's available?
Tell us what you need and we can source it for you.

Product Summary

Downloads (4): Spec Sheet, Manual, Dimensions and more
Current Connected
×
Victron

Current Connected is YOUR Victron product specialist

Explore Lineup

Frequently Asked Questions

Victron sells three versions of the MultiPlus-II 48/5000/70-95 120V. PMP482505110 is the standard model, PMP482505120 adds the UL 1741 and UL 458 listings, and PMP482505300 is a 50/60Hz version. We stock the PMP482505120. For an inspected install or one that needs utility sign-off, the UL 1741 listing is the one to have.

The AC input current limit is set below what your circuit can supply, so PowerAssist starts leaning on the batteries early. One customer saw the batteries take over everything above about 2,000W for exactly this reason. Set the input current limit in VictronConnect to match your breaker or generator, and the grid or generator carries more of the load.

Yes. A grid-tie PV inverter on the MultiPlus-II's output can run loads and charge the bank, and when the batteries are full the MultiPlus-II raises its output frequency to throttle the PV inverter back. The PV inverter has to support frequency shifting. Victron's Factor 1.0 rule caps AC-coupled PV at the inverter charger's VA rating, so up to 5,000W here, and its AC coupling guide calls for roughly 4.8kWh of lithium storage for every 1.5kW of PV. DC-coupled solar through a SmartSolar MPPT charge controller charges the bank directly and falls outside the Factor 1.0 rule.

Yes. Victron supports lithium banks that have a BMS monitoring and controlling the cells, and its guide, Connecting other lithium battery systems to Multis and Quattros, covers which batteries work and how to set each one up. Batteries that talk over CAN-bus connect to the system through a GX device.

No. Victron doesn't supply the temperature sensor with 48V models, so add one if you charge lead-acid batteries and want temperature-compensated charging. On a lithium bank, the BMS normally handles temperature protection.

No. Once it's programmed, the MultiPlus-II runs on its own. A GX device earns its place when you want ESS or a CAN-bus link to a smart lithium battery.

It can run grid-interactive as part of a Victron ESS and carries a UL 1741 listing, but export is up to your utility. Get interconnection approval before you set the system to feed back, and check with your AHJ (Authority Having Jurisdiction).

Videos

Victron 5kVA 48V MultiPlus-II - Breakthrough Technology?

Victron 5kVA 48V MultiPlus-II - Breakthrough Technology?

YouTube
Victron Split Phase Configuration Guide

Victron Split Phase Configuration Guide

YouTube

Customer Reviews (2)

4.5
kmkrreevesNovember 27, 2025 Verified Purchase

Great units

I have 2 set up for split phase. Charging and inverting work flawlessly. The UPS function is amazing. Really enjoy these units.

JrestabrookDecember 3, 2024 Verified Purchase

Everything works perfect, except load assist. Running under 2,000 watts it pulls 2,000 watts from grid to run things and charge the batteries. Anything over 2k lowers the grid draw and drains the batteries.

Dexter MonroeDecember 12, 2024

Thank you for the feedback! This can be changed in programming by adjusting the input current limit. Our team is happy to assist if you would like to call / email us!