Best technical support
The reason i keep buying my gear with CC is because they have the best, most efficient and friendliest technical support.
SKU: Please select an option...

Log in to check member price and detailed stock information.
Please select all options above to add to cart.
The Victron SmartSolar MPPT RS 450/100 and 450/200 charge a 48V battery bank at up to 200A from PV strings as high as 450V, with every string on its own independent tracker. Long high-voltage strings run on lighter wire and plug straight into their own MC4 inputs, so east roofs, west roofs and partly shaded arrays all harvest at their own peak on one controller.
100A (5,760W) on the 450/100 or 200A (11,520W) on the 450/200, charging 48V lithium or lead-acid banks
Two independent MPPT trackers on the 450/100 and four on the 450/200, each with its own pre-wired MC4 pair
450V max PV open-circuit voltage, 65V to 450V tracking range, 120V to start charging
Up to 4,000W of charge power and a 7,200Wp array per tracker, at 16A operating and 20A short-circuit current
Galvanic isolation between PV and battery, with PV ground-fault monitoring that flags faults below 100kΩ
Built-in display, Bluetooth setup, programmable relay and synchronized charging across up to 25 units
96% peak efficiency, full output to 104°F (40°C), rated -40°F to 140°F (-40°C to 60°C) for indoor mounting (IP21)
M8 battery studs (two on the 450/100, four on the 450/200) and Victron's 5-year warranty

Current Connected is YOUR Victron product specialist
The SmartSolar MPPT RS is Victron's high-voltage solar charge controller for 48V battery banks, built for arrays that are big, spread out, or both. Instead of combining strings into one input, it gives each string its own independent MPPT tracker: two on the 450/100 and four on the 450/200. Mix panel models, string lengths, tilts and roof faces on one controller, and each string still runs at its own maximum power point.
Strings up to 450V carry less current for the same power, so long runs from a ground mount or a detached shop roof can use lighter wire with less voltage drop. The 450/100 charges at up to 100A (5,760W) and the 450/200 at up to 200A (11,520W), straight into the same 48V bank your inverter runs from.
Split an array across east, south and west faces, each on its own tracker, and production starts earlier and holds later in the day. The east string catches the morning sun, the west string takes over in the afternoon, and the result is a flatter, wider power curve. For off-grid systems trying to top off the batteries before sunset, that late-afternoon harvest is often worth more than a higher noon peak.
Shade works the same way. A tree shadow on one string pulls down only that tracker, while the other strings keep running at their own peak.
Each tracker delivers up to 4,000W of charge power, and Victron rates each one for a PV array of up to 7,200Wp (450V × 20A short-circuit). That headroom lets you oversize a string so it reaches full charge power earlier in the morning, later in the evening and on cloudy days, with the controller trimming the midday peak.
Size strings for the coldest morning at your site, because panel voltage climbs as temperature drops. Victron recommends keeping an extra 10% margin under the 450V limit, since overvoltage damage isn't covered by warranty.
The battery sets a second limit. Array open-circuit voltage has to stay below 8 times the float voltage, so a bank floating at 54.0V caps the array at 432V. Above that, the controller stops with an over-charge protection error until the float setting goes up or a panel comes off the string. Our team is happy to help with sizing before you order panels.
The 450/100 runs up to two strings on a 48V bank of at least 50Ah lithium or 200Ah lead-acid. The 450/200 is a 200 amp charge controller for up to four strings, and Victron's minimum bank for it is 100Ah lithium or 400Ah lead-acid. Bigger systems can run up to 25 units in parallel, with charge stages synchronized across all of them.
Full galvanic isolation separates the high-voltage PV side from the 48V battery side for added system safety. The controller also tests PV positive and negative to ground continuously and flags a fault if insulation drops below 100kΩ, which catches damaged wire, chafed conduit runs or water intrusion early. It reports the error at the unit, and to a GX device if one is connected, while charging continues.
Victron requires both PV conductors to stay isolated from ground, so the array runs ungrounded. Ground the array frames and the controller's chassis lug per local code, with a grounding conductor at least as large as the PV wire.
Victron specifies installation under the supervision of a qualified installer, and the PV side comes down to two parts. First, plan an external DC disconnect between the array and the controller, rated for at least 450V and the array's short-circuit current. The IMO SI32-PEL64R rooftop isolator switches both conductors of every string at 600V and 32A per string, in a 4-pole version for the 450/100 and an 8-pole version for the 450/200.
Second, each tracker has a pre-wired pair of MC4 connectors on the bottom of the unit, so strings plug in without opening the wiring compartment. Victron specifies Stäubli MC4 connectors to mate with them, and our Stäubli MC4 and PV wire installation bundle includes the connectors, PV wire and the Stäubli crimper.
Victron recommends a 125A to 150A DC fuse on the 450/100 and a 250A fuse on the 450/200. On a Lynx Distributor or other MEGA fuse holder, genuine Littelfuse MEGA fuses cover both sizes for the controller's branch circuit.
For runs up to 6.5 ft (2 m), Victron's minimum per battery terminal is 35 mm² on the 450/100 and 70 mm² on the 450/200, which our custom battery cables cover in 1/0 AWG and 4/0 AWG. Runs up to 16.4 ft (5 m) double that: 70 mm² (4/0 AWG) on the 450/100 and two 70 mm² cables (two 4/0 AWG) per terminal on the 450/200. Order 5/16" lugs for the M8 studs, and torque the nuts to no more than 10.3 ft-lb (14 Nm).
Mount the controller vertically indoors, with 12 in (30 cm) of clear space above and below for the cooling fans, and keep it out of the space directly above lead-acid batteries.
The four-line backlit display shows battery voltage, charge current, each tracker's voltage and current, and error codes. Bluetooth connects to the VictronConnect app for setup and live monitoring, with eight battery presets and a fully programmable charge curve from 36V to 60V.
For lithium banks, the remote input works as a BMS allow-to-charge signal, so the battery's BMS can stop charging directly. Wired voltage and temperature sensing keep the charge voltage accurate at the battery terminals, and the programmable relay can trigger an alarm or start and stop a generator.
It's a 48V-only controller, with a programmable charge range of 36V to 60V. For 12V and 24V systems, Victron's smaller SmartSolar MPPT controllers cover those battery voltages.
Each tracker accepts up to 16A operating current and 20A short-circuit current, so two parallel strings only work if their combined short-circuit current stays at or under 20A. Check the short-circuit rating on your panel datasheet: with panels above 10A, plan on one series string per tracker and step up to the 450/200 when you need more strings. Victron also notes that more than 20A connected in reverse polarity can damage the controller.
Daisy-chain up to 25 units with RJ45 network cables between their VE.Can ports, with a VE.Can terminator at each open end of the chain. Give every unit identical settings and its own array, since synchronized units can't share PV inputs. Charge stages then stay in sync automatically, and each unit regulates its own output for its array and cable run.
No. The MPPT RS runs on its own, with setup and monitoring over Bluetooth. A GX device adds VRM remote monitoring, control from managed lithium batteries and Victron ESS systems, and audible or email alarms for PV ground faults (email alarms need an internet connection and a VRM account). At remote sites, a GlobalLink 520 also connects the controller to VRM.
The MPPT RS uses its own wired voltage and temperature sense terminals instead. Victron notes it doesn't currently support VE.Smart networking, so wireless sensors like the Smart Battery Sense won't link to it.
The MPPT RS has no rapid shutdown function of its own, and its remote input controls charging only, so the array wiring stays energized whenever the panels see light. On rooftop arrays, NEC 690.12 rapid shutdown is typically handled at the modules with module-level shutdown devices. Check with your AHJ (Authority Having Jurisdiction) on what your install requires, and our team can help match a solution to your array.
The reason i keep buying my gear with CC is because they have the best, most efficient and friendliest technical support.
i have the 450V/200A, this is the best controller ive ever used, its fast quiet and efficent and will work until the last ounce of light avalable.
I just completed installation and start-up of the 20K 120/240 Kit system, three 25K S0K battery racks, and forty-two 400W Rich Solar panels. A well-designed system and knowledgeable staff made the installation and start-up a breeze. The well thought out complete package was beyond expectation, in every detail. Oversized cables hydraulically crimped with heat shrink and protective covers. No missing parts! The equipment was everything as described, top quality, very knowledgeable staff. I cannot say enough good things about the product and service. The equipment was package and shipped on time, in very heavy-duty crates, on pallets organized in a way that made the installation simple and straight forward. Everything worked the first time. I am now producing more electricity than I need! I am using all the equipment, A/C, refrigerators, freezers, and well pump, with plenty of power to recharge the battery bank every day. Worth every penny. I am now energy independent. I now use the public utility as my back-up source. Doubt I’ll ever need them. I have been in business for over 40 years, have dealt with hundreds of suppliers, and I can say I have never had a better experience. 100 star rating!