Additional information
Weight | 32 lbs |
---|---|
Dimensions | 14 × 11 × 11 in |
*10 year warranty only applies to batteries purchased through Currentconnected.com
Weight | 32 lbs |
---|---|
Dimensions | 14 × 11 × 11 in |
General settings that apply to most equipment. For Victron BlueSmart Chargers, please refer to the BlueSmart product listing page for exact parameters.
Multiply voltages by 2 for 24v systems and by 4 for 48v systems.
Charge Current (Per battery): 40a Preferred (50a Maximum)
Absorption Voltage: 14.6v preferred (14.4 Minimum)
Float Voltage: 13.8v preferred (13.6 Minimum)
Equalization: DISABLED
Low Voltage Disconnect (LVD): 11v
Equalization:
MUST BE DISABLED. SET DURATION TO 0 MINUTES.
If you can, we recommend setting the equalization voltage to 14.6v. With this set at 14.6, if an equalization is somehow triggered, you will not damage your battery.
Battery Capacity: Varies depending on system.
Charged Voltage: 13.8 (*2 for 24v & *4 for 48v Systems)
Discharge Floor: 10%
Tail Current: 2.00%
Charged Detection Time: 3m
Peukert Exponent: 1.05
Charge Efficiency Factor: 98%
Current Threshold: 0.10a
Time-to-go averaging Period: 3m
Battery Starts Synchronized: Disabled (NOTE: you will need to fully charge your battery to sync up SOC%)
State of Charge: 30% (NOTE: Set this to 30% with brand new, untouched batteries. They ship at 30% SOC%.)
Comment on Discharge floor:
Let’s say you setting this at 10%; when you get to 10%, the Smartshunt will indicate 10% remaining and 0 minutes until empty. If you choose to fully discharge your battery (not recommended) then set this to 0%. If you want to be more conservative on your time remaining, then set this to 20%
Battery Voltage: Set depending on system, normally 12v.
Max Charge Current: OK to set as high as desired, but no more than 50a per battery
Charger: Enabled
Battery Preset: User Defined
Expert Mode: ON
Absorption Voltage: 14.6v
Float Voltage: 13.8v
Equalization Voltage: 14.6v
Rebulk Voltage Offset: 0.40v
Absorption Duration: Fixed
Absorption Time: 15 Minutes (This allows for proper cell balancing)
Tail Current: Disabled
Equalize Current: 0% (For safety we don’t want equalization at all.)
Automatic Equalization: Disabled
Equalize Stop Mode: Automatic (On voltage)
Maximum Equalize duration: 0 Minutes
Manual equalization: DO NOT CLICK START
Temperature Compensation: Disabled
Low Temperature Cutoff: Disabled (unless you add a temp sensor, the BMS has this protection built in)
IMPORTANT: For battery type, select “USER”
High Voltage Disconnect: 15.0
Charge Limit Voltage: 14.6v
Equalize Charge Voltage: 14.4
Boost Charge Voltage: 14.6v
Float Charge Voltage: 13.8v
Boost Charge Return Voltage: 13.4
Over Discharge Return Voltage: 12.0v
Low voltage Alarm:11.8v
Over Discharge Voltage: 11.0v
Discharge Limit Voltage: 10.5
Over Discharge Delay Time: 5 Seconds
Equalize Charge Time: 0
Boost Charge Time: 15 Minutes
Equalize Charge Interval: 0